ꄙ Search
  • 简体中文
  • English
  • Products Products
    • Wieland
    • Kemper
    • Aalberts
  • Solutions Solutions
    • Drinking water hygiene
    • Heating/Cooling
  • Applications Applications
  • About Us About Us
    • Showroom

Categories

MULTI-THERM thermostatic balancing valve

figure 141 0G

• control range 50°C - 65°C

• thermostatic balancing valve for hydraulic balancing of riser and distribution pipes

• for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection

• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water

• male union thread

stop valve

MULTI-THERM thermostatic balancing valve, union thread, 50°C - 65°C

뀠
녓 Learn More
녔 All Products

figure 143 00

• control range 50°C - 65°C

• thermostatic balancing valve for hydraulic balancing of riser and distribution pipes

• for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection

• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water

• female pipe thread

stop valve

MULTI-THERM thermostatic balancing valve, FPT, 50°C - 65°C

뀠

figure 143 22

• control range 50°C - 65°C

• thermostatic balancing valve for hydraulic balancing of riser and distribution pipes

• for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection

• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water

• press connection for Geberit MAPRESS pipe

stop valve

MULTI-THERM thermostatic balancing valve, MAPRESS, 50°C - 65°C

뀠

figure 041 0G

• control range 50°C - 65°C

• thermostatic balancing valve for hydraulic balancing of riser and distribution pipes

• for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection

• wetted parts made of stainless steel

• male union thread

stop valve

SST MULTI-THERM thermostatic balancing valve, 50°C - 65 °C, union thread

뀠

figure 140 0G

• control range 30°C - 50°C

• thermostatic balancing valve for hydraulic balancing of riser and distribution pipes

• for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection

• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water

• male union thread

stop valve

THERM thermostatic balancing valve, union thread, 30°C - 50°C

뀠

figure 142 00

• control range 30°C - 50°C

• thermostatic balancing valve for hydraulic balancing of riser and distribution pipes

• for hydraulic balancing of hot water return systems (PWH-C), supports thermal disinfection

• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water

• female pipe thread

stop valve

THERM thermostatic balancing valve, FPT, 30°C - 50°C

뀠
  • Stop Valves ꁕ
    • Stop Valves with Flanges
    • WESER Stop Valves
    • ECO Stop Valves
    • STANDARD Stop Valves
    • Quarter Turn Stop Valves
    • Stainless Steel Stop Valves
  • Safety Valves ꁕ
    • Anti-pollution check valve and combined stop and check valves
    • Backflow preventer, type CA
    • Reduced-pressure-zone backflow preventer BA, RPZ-Valve
    • Break tank stations
    • Leak Detection System
    • Safety Groups
  • Pressure Reducing Valves and Filter
  • Balancing valves ꁕ
    • MULTI-THERM thermostatic balancing valve
    • ETA-THERM thermostatic balancing valve
    • Manual Balancing Valves
  • Measuring Products
  • Hygiene System KHS ꁕ
    • KHS Flow-Splitter
    • KHS CoolFlow cold water circulation
    • KHS Hygiene Flush Boxes
    • KHS Temperature Sensors
    • KHS Flush Points
    • KHS Control Systems
    • KHS flushing components
  • Thermal separators
  • Flush-mounted valves
  • Stop valves water meter combinations ꁕ
    • Stop valve water meter combinations
    • stop valve_water meter combination
    • Stop valve water meter boxes
  • Frost-proof outdoor taps
  • TRESOR Cabinets ꁕ
    • TRESOR Built-In Wall Cabinet
    • TRESOR built-in wall cabinet for chlorinated environments (e.g. swimming baths)
    • TRESOR Surface-Mounted Wall Cabinet
    • MINI-TRESOR Built-In Wall Cabinet
    • MINI-TRESOR Surface-Mounted Wall Cabinet
  • Sampling Valves
  • ThermoSystem KTS ꁕ
    • The new generation of KTS Water Heaters
    • Components for KTS Water Heaters
    • KTS ThermoTank S
    • Components for KTS ThermoTanks
  • Other Valves
  • Accessories ꁕ
    • Connection Flanges
    • Union Connections
    • Insulation Shells
    • Drain Valves
    • Accessories for Safety Valves
    • Accessories for PRV / Filter
    • Accessories for Balancing- and Measuring Valves
    • Accessories for KHS
    • Accessories for Water Meter Valves
    • Accessories for Frost-Proof Outdoor Valves
  • Spare parts ꁕ
    • Spare parts for stop valves
    • Spare parts for protection and safety valves
    • Spare parts for pressure reducing valves and filters
    • Spare parts for balancing valves
    • Spare parts for measuring products
    • Spare parts for sampling valves
    • Spare parts for flush-mounted valves
    • Spare parts for stop valve water meter models
    • Spare parts for frost-proof outdoor taps
    • Spare parts for TRESOR cabinets
    • Spare parts for hygiene system KHS
    • Spare parts for dirt traps
    • Handwheels and gaskets

 

The MULTI-THERM automatically adjusts the hydraulic balancing depending on the temperature in circulation lines of the hot drinking water.

Circulation balancing valves must allow water to circulate at all times. Water must be able to continue to flow even after the target temperature is reached. Particularly for thermal disinfection, it is important for the water to be able to circulate continuously at a high temperature so that the circulation pump does not work against closed valves. These technical requirements are met by the MULTI-THERM.

With a factory setting of 58°C, the valve is fully open up to a valve temperature of approximately 53°C.

From 53°C pressure is lost due to the temperature-dependent cross-sectional change in the valve. When the target temperature reached, valve throttle position is set to its maximum, whereby a minimum volume constantly flows in the circulation system. The MULTI-THERM also supports the thermal disinfection.

Shut off, measure, drain

An immersion sleeve is integrated in the bonnet of the stop valve. A Pt 1000 temperature sensor (1) or a plug-in thermometer (2) can be used as an alternative to the attached handle. Temperature data can thus also be transmitted via the building management system or via the CONTROL-PLUS hand-held measuring device. Furthermore, a drain valve (3) can be installed on the MULTI-THERM to drain the line.

MULTI-THERM thermostatic balancing valve

Links:

Wieland Wieland
Keibo Kemper
Albert Aalberts
Albert Aalberts
All Copyright Reserved Beijing Hongta Environment Engineering Co. Ltd

Tel.: 400-610-5500

E-Mail: sales@hongtaclima.com

 Follow us

WeChat Official Account

TikTok

About Us

  • Hongta in Brief
  • Showroom
  • Wieland
  • Kemper
  • Aalberts

Brand Products

  • Press releases
  • Fairs and events

News 

Solutions

  • Drinking water hygiene
  • Heating or cooling
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6
 本网站由阿里云提供云计算及安全服务
本网站支持 IPv6