Categories
KHS Flow-Splitter
figure 650 00
• prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
• KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
• maintenance free
• including quarter turn stop valves, female threaded, for flush-mounted installation, figure 585 00
KHS Flow-Splitter unit - dynamic, for flush mounted installation
figure 650 06
• prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
• KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
• maintenance free
• including KHS stop valve, female threaded, figure 385 00
KHS Flow-Splitter unit - dynamic, FPT
figure 650 02
• prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
• KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
• maintenance free
• including KHS stop valves, union thread, figure 386 0G
KHS Flow-Splitter unit - dynamic, union thread
figure 650 20
• prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC) and hot drinking water (PWH)
• KHS Flow-Splitter - dynamic, according to the Venturi principle, including dynamic cartridge, flow and return branch for connection of outlets / plumbing units
• wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water
• maintenance free
KHS Flow-Splitter set - dynamic
figure 640 50
• for use exclusively in single and two-family houses
• prevents stagnation in ring pipe installations through forced flow during downstream withdrawals, can be used in cold drinking water (PWC)
• venturi technology creates parallel flow through main and loop pipe
• for flush mounted installation or in unaccessible locations
• maintenance free
KHS Flow-Splitter box, for in-floor installation
- Stop Valves ꁕ
- Safety Valves ꁕ
- Pressure Reducing Valves and Filter
- Balancing valves ꁕ
- Measuring Products
- Hygiene System KHS ꁕ
- Thermal separators
- Flush-mounted valves
- Stop valves water meter combinations ꁕ
- Frost-proof outdoor taps
- TRESOR Cabinets ꁕ
- Sampling Valves
- ThermoSystem KTS ꁕ
- Other Valves
- Accessories ꁕ
-
Spare parts
ꁕ
- Spare parts for stop valves
- Spare parts for protection and safety valves
- Spare parts for pressure reducing valves and filters
- Spare parts for balancing valves
- Spare parts for measuring products
- Spare parts for sampling valves
- Spare parts for flush-mounted valves
- Spare parts for stop valve water meter models
- Spare parts for frost-proof outdoor taps
- Spare parts for TRESOR cabinets
- Spare parts for hygiene system KHS
- Spare parts for dirt traps
- Handwheels and gaskets
The manual, static addition
In circulation circuits, only the first balancing valve may be thermostatically controlled. For systems with several hydraulic levels, therefore, additional static balancing valves are required! The MULTI-FIX-PLUS allows fine volume flows to be set on the basis of the valve setting values that have been defined. The setting values can be determined by fastening to the handwheel. Furthermore, the valve can be used during maintenance work, for example, for shutting off the pipework.
Ensure lasting drinking water hygiene
The stage for ensuring sustainable and efficient drinking water hygiene has already been set when it comes to selecting the installation type. In ring installations, KHS Flow-Splitters make it possible to perform 100 water exchanges a day in potential stagnation areas without auxiliary energy or additional flushing measures. Natural draw-offs cause drinking water to be exchanged in all upstream bathrooms. And Flow-Splitter installations don't just ensure drinking water hygiene through preventing stagnation, as comparatively up to 5K lower temperatures are achieved through regularly flowing fresh drinking water in the bathroom installation, ultimately making temperature maintenance < 25°C considerably more efficient.
In conjunction with additional system components such asKHS Hygiene Flush BoxorKHS CoolFlowthe water exchange and temperature maintenance can even be implemented in phases of the interruptions to operations in an automated manner - sustainable, economical and resource-friendly.
How does a Flow-Splitter work?