Categories
KHS Flush Points
figure 684 00
• complete Flush Point for automatically triggering water change to ensure proper operation
• for pressure independent flow limitration
• wetted metal parts made of stainless steel and gunmetal
• free from dead spots
KHS Flush Point, 24V
figure 684 01
• complete Flush Point for automatically triggering water change to ensure proper operation
• CONTROL-PLUS flow and temperature sensor, 4-20 mA
• for pressure independent flow limitration
• wetted metal parts made of stainless steel and gunmetal
• free from dead spots
KHS Flush Point, 24 V, with CONTROL-PLUS
figure 684 04
• complete Flush Point for automatically triggering water change to ensure proper operation
• for pressure independent flow limitration
• wetted metal parts made of stainless steel and gunmetal
• free from dead spots
KHS Flush Point, 230V
figure 684 05
• complete Flush Point for automatically triggering water change to ensure proper operation
• CONTROL-PLUS flow and temperature sensor
• for pressure independent flow limitration
• for integration in existing KHS mini control system
• wetted metal parts made of stainless steel and gunmetal
• free from dead spots
Products
KHS Flush Point, 230 V, with CONTROL-PLUS
- Stop Valves ꁕ
- Safety Valves ꁕ
- Pressure Reducing Valves and Filter
- Balancing valves ꁕ
- Measuring Products
- Hygiene System KHS ꁕ
- Thermal separators
- Flush-mounted valves
- Stop valves water meter combinations ꁕ
- Frost-proof outdoor taps
- TRESOR Cabinets ꁕ
- Sampling Valves
- ThermoSystem KTS ꁕ
- Other Valves
- Accessories ꁕ
-
Spare parts
ꁕ
- Spare parts for stop valves
- Spare parts for protection and safety valves
- Spare parts for pressure reducing valves and filters
- Spare parts for balancing valves
- Spare parts for measuring products
- Spare parts for sampling valves
- Spare parts for flush-mounted valves
- Spare parts for stop valve water meter models
- Spare parts for frost-proof outdoor taps
- Spare parts for TRESOR cabinets
- Spare parts for hygiene system KHS
- Spare parts for dirt traps
- Handwheels and gaskets
The water exchange required by the relevant standards is one of the fundamentals for maintaining drinking water hygiene. To ensure the flawless functioning of a drinking water installation the designer has to take the maximum usage situation into consideration. In practice, however, this maximum usage is not the usual situation. Stagnating sections and insufficient hygiene in both the cold drinking water (PWC) and the hot drinking water (PWH) can be the consequence. Changes in the type of use or the behaviour of the building's users have a similar effect. Over a building's lifetime, the actual frequency of withdrawals and volumes deviates strongly from the originally intended values. In both cases, the intended use can no longer be ensured.
The KHS Flush Point helps to ensure the intended use through controlled 'forced withdrawals '.
The KHS Flush Point is available in four different designs. These can ensure the intended use in combination with other KHS control systems or the building management system (BMS). The time, temperature and volume parameters of the water exchange can be controlled.