Categories
Break tank stations
figure 369 00
• for the protection of drinking water against non-potable water of fluid category 5 in accordance with DIN EN 1717/DIN 1988-100
wetted parts on the drinking water side made of gunmetal, stainless steel and drinking water approved plastics
• with coupling nut for flat sealing connection thread including EPDM gasket
FK-5 break tank station
- Stop Valves ꁕ
- Safety Valves ꁕ
- Pressure Reducing Valves and Filter
- Balancing valves ꁕ
- Measuring Products
- Hygiene System KHS ꁕ
- Thermal separators
- Flush-mounted valves
- Stop valves water meter combinations ꁕ
- Frost-proof outdoor taps
- TRESOR Cabinets ꁕ
- Sampling Valves
- ThermoSystem KTS ꁕ
- Other Valves
- Accessories ꁕ
-
Spare parts
ꁕ
- Spare parts for stop valves
- Spare parts for protection and safety valves
- Spare parts for pressure reducing valves and filters
- Spare parts for balancing valves
- Spare parts for measuring products
- Spare parts for sampling valves
- Spare parts for flush-mounted valves
- Spare parts for stop valve water meter models
- Spare parts for frost-proof outdoor taps
- Spare parts for TRESOR cabinets
- Spare parts for hygiene system KHS
- Spare parts for dirt traps
- Handwheels and gaskets
Fluid category 5 safety valves
KEMPER FK-5 break tank stations protect drinking water from non-potable water up to and including fluid category 5. Due to the significant risk to human health caused by category 5 fluids, indirect separation from the drinking water system must be ensured. The FK-5 break tank station meets this requirement through an integrated free type “AB” drain. And it also has many functional highlights!
Benefit from the following advantages:
- High-level performance: flow rate up to 7 m³/h (in combination with the FK-5 water supply set plus, Figure 369 01)
- Promotes drinking water hygiene through programmable flushing cycles for the drinking water feed pipe
- Integrated tank cleaning program
- Controls operating time via weekly program
- Controls an external dosing or submersible pump
- Reading of consumption and operating data via USB port
- Fault signal output to BMS
Definition of fluid category 5 based on DIN EN 1717
Fluid that presents a health hazard for human beings through the presence of microbial or viral pathogens of infectious diseases (contamination, danger to life).
Practical use examples:
- Subsurface irrigation
- Use in a microbiological laboratory
- Cooling towers
- Water for drinking troughs
- Water playgrounds
- Cleaning processes in the zoological sector
You can find more information on choosing the right safety valves in our guidebook.
FK-5 break tank stations
About Us
Solutions